Pre-launch · design-partner fleets wanted

01Ionaria

See inside every battery you run.

Ionaria builds a physics-ML twin of each cell and pack from the telemetry you already log. It forecasts wear, adapts charging and cooling, and flags thermal-runaway risk while there is still time to act.

P-0412 · LFP 96s · depot 3Example

Reading voltage, current and temperature from the BMS…

Pack state of health
—
Remaining useful life
—
Hottest cell vs. twin
—

Cell 3-11 Nominal

No action needed.

ApproveEdit
Drawn example. The pack, readings and forecast are illustrative, not from a real fleet.

02Targets

What we are building toward.

Design targets for the first pilots, not results. We will publish measured numbers per chemistry as pilots finish.

+20%

more usable life per pack

Design target

< 100 ms

edge warning at the BMS

Design target

±3%

state-of-health error

Design target

1 twin

per cell, recalibrated daily

Design target

03Problem

Batteries are run on guesswork.

The most expensive part of every electric bus, truck and storage site is managed by static rules and a single state-of-health number.

  • Packs are retired early or over-provisioned because nobody trusts the forecast.
  • Charging and cooling follow worst-case rules that cost life, capacity and speed at once.
  • Thermal runaway shows faint signs first, and shallow dashboards miss them.
  • Every chemistry ages differently, so last year’s model is wrong for this year’s cells.

05How it works

From BMS log to approved action.

  1. 01

    Connect

    Read BMS and telematics data you already have: voltage, current, temperature, cycles. No new hardware to start.

  2. 02

    Twin

    Cellix fits a physics-ML twin to each pack and keeps it calibrated as new data arrives.

  3. 03

    Forecast

    State of health and remaining life per pack, with the reasons behind them.

  4. 04

    Protect and optimize

    Sentinox watches for runaway precursors. Voltari proposes charge and cooling policies.

  5. 05

    Act

    Cortova turns findings into tickets, schedules and limits, and waits for approval.

06Who it’s for

Built for the people who own the asset.

07Size it

How much battery are you guessing about?

112 MWh

under management

16.8 MWh

of capacity sitting idle or retired early

60

packs’ worth of capacity

MWh = packs × kWh ÷ 1,000. Idle = MWh × the share you set. Planning arithmetic, not a forecast of savings. Illustrative.

08Under the hood

GPU physics, not dashboards.

Physics-informed models trained on NVIDIA GPUs, served by API and at the edge.

  • ModulusPhysics-ML surrogates
  • RAPIDSFleet telemetry on GPU
  • OmniversePack and site twins
  • IsaacRL in simulation
  • NeMoOps copilot and guardrails
  • JetsonEdge protection at the BMS
  • TritonTwin-state serving
  • TensorRTLow-latency inference
GET /v1/packs/P-0412/twin-stateExample
{
  "pack": "P-0412",
  "chemistry": "LFP",
  "soh": 0.914,
  "rul_cycles": 1830,
  "drivers": ["SEI growth", "lithium plating risk at > 1.2C below 10 °C"],
  "hottest_cell": { "id": "3-11", "delta_t_c": 4.2 },
  "twin_version": "clx-lfp-2026.11.3"
}

09Questions

Straight answers.

Do we need new sensors?

No. Ionaria starts from data your BMS and telematics already log. Extra sensors, such as off-gas detectors, sharpen safety warnings later.

Which chemistries?

LFP and NMC first. Sodium-ion and solid-state are on the roadmap.

Does Ionaria control our chargers?

Only if you choose it. It starts as advice, moves to approved actions, and never changes a safety limit without a named approver.

Is this a replacement for our BMS?

No. Your BMS stays in charge of protection. Ionaria adds a twin, forecasts and a second, earlier warning.

10Next step

Send one month of cycle data. Get one pack twin back.

Export a month of BMS telemetry from a few packs. We return a calibrated twin, a state-of-health and remaining-life estimate per pack, and the three cells we would watch first.