Synthael
01SYN · Simulate
Failure data you could never safely collect.
Real fleets produce very few runaway events, and nobody should create more. Synthael runs physics-grounded failure scenarios on Cellix twins to give safety models the examples they need.
- Scenario
- SC-0091 nail, LFP
- Variants
- 12,000
- Peak cell temp
- 512 °C
- Propagates
- 2 of 12 cells
Example One simulated scenario. Illustrative.
02Capabilities
What Synthael does.
01
Scenario library
Thermal, electrical, mechanical and abuse events, by chemistry and format.
02
Physics-grounded
Each run comes from a Cellix twin, not a guess.
03
Variation at scale
Thousands of variants per scenario: ageing, temperature, load.
04
Labelled
Every sample says what happened, where and when.
05
Validation sets
Held-out scenarios to test a safety model before it ships.
06
Fidelity scores
How close each simulation is to lab data (planned).
03Scenario catalogue
Filter the library.
- abuseNail penetration, LFP prismaticLFP · Cell to module propagation
- abuseExternal short, NMC pouchNMC · Cell
- electricalOvercharge at 0 °CNMC · Cell
- thermalCooling-plate blockage, depot heat waveLFP · Pack
- electricalLithium plating after fast charge in coldNMC · Cell
- thermalVenting in an enclosed BESS containerLFP · Rack to container
- mechanicalBusbar loosening under vibrationNMC · Module
- abuseInternal short from manufacturing particleSodium-ion · Cell
- thermalFan failure during summer peak shavingLFP · Rack
Example A sample of the scenario library we plan to build. Titles describe simulated events, not incidents at any company.
04How it works
Step by step.
- 01
Pick
Choose a scenario, chemistry and format.
- 02
Vary
Sweep age, temperature, current and defects.
- 03
Simulate
Run on GPU with Cellix twins in Omniverse; Cosmos for world-model synthesis (planned).
- 04
Check and ship
Compare with lab data where it exists; deliver labelled data.
05Specification
The details.
| Item | Detail |
|---|---|
| Scenarios | Thermal, electrical, mechanical, abuse |
| Chemistries | LFP, NMC; sodium-ion (planned) |
| Formats | Parquet, HDF5 |
| Compute | DGX/HGX, Omniverse |
| Use | Internal training for Sentinox and Cellix; external subscription (planned) |
07Questions
Straight answers.
Is synthetic data trustworthy?
Only when checked. We compare runs with lab abuse tests and publish a fidelity score per scenario (planned).
Can we license the data?
We plan a scenario-library subscription for cell makers and OEMs.
Do you simulate our exact cell?
Yes, once Cellix has a twin of it.
08Next step
Send one month of cycle data. Get one pack twin back.
Export a month of BMS telemetry from a few packs. We return a calibrated twin, a state-of-health and remaining-life estimate per pack, and the three cells we would watch first.